Suspendisse efficitur metus vitae lectus finibus interdum. Praesent consectetur, tortor in sodales ultricies, purus enim venenatis ante, et consequat mi lacus at nulla. Proin sed nibh eu dui tempus convallis. Maecenas tristique leo justo, vel malesuada velit maximus vel. Curabitur molestie commodo placerat.

Download now IMST-ART latest version

IMST-ART© Version 4.10

Released:
  • Improved charge calculation.
  • New component: Subcooler.
  • Improved model for compressor:
    • Heat Losses depending on rpm.
    • OCR depending on rpm.
    • External Inverter Efficiency depending on Power Input.
    • Oil Solubility, Motor Cooling, Internal Leakage.
    • Define Mass Flow Rate in catalogue.
  • Improved model for Plates Heat Exchangers:
    • Asymmetric Plate Pitch.
    • Port Volume definition.
  • Improved “Export to Excel” feature.
  • Dead Charge in cycle.
  • Fixed some minor bugs on models calculation.
  • Fixed some minor bugs on GUI.

IMST-ART© Version 4.00

Released: February, 2021
  • Optimized for Windows 64-bit.
  • New control for grids.
  • It is possible to calculate up to 5000 cases using parametric studies.
  • Parametric Studies Dialog allows adding/removing multiple cases simultaneously (new “Add/Remove Cases” buttons).
  • Catalogue Data Compressors allow the definition of inverter compressors (with catalogue data for different speeds).
  • Improved calculation model for catalogue data compressors.
  • New refrigerants available: R365mfc, R1224ydz, R1233zde, R1234zez, R1366mzz(z), R1123, R1243zf, butene, pentane, R466A, eglycol.
  • Improved refrigerant maps.
  • Fixed some minor bugs on models calculation.
  • Fixed some minor bugs on GUI.

IMST-ART© Version 3.90

Released: June, 2019
  • Improved calculation engine (up to 50% faster than previous versions).
  • It is possible to calculate two different cycles simultaneosuly.
  • It is possible to calculate up to 1000 cases using parametric studies.
  • If there are errors when calculating any case, calculation continues with the rest of cases.
  • In results window, error cases are shown in red.
  • In results window, buttons for showing Warnings and Errors.
  • Fixed some minor bugs on models calculation.
  • Fixed some minor bugs on GUI.

IMST-ART© Version 3.8

Released: April, 2017
  • Microchannel Heat Exchanger model available (as condenser and evaporator for Working Cycle and Stand Alone HE).
  • Improvements in Fan/Pump calculation (improved model and new input data available).
  • Improved maps for all refrigerants (improved accuracy).
  • New input data for Plates HE (Area EnhF).
  • New input data for compressors (External Inverter Efficiency).
  • Installation on “Program Files” folder (“Program Files(x86)” for Windows 64 bits) valid for all computer users.
  • Administrator privileges needed for installing, activating and reactivating the license (not needed for executing).
  • Fixed some minor bugs on models calculation.
  • Fixed some minor bugs on GUI.

IMST-ART© Version 3.7

Released: October, 2015
  • New Microchannel Heat Exchanger model available for Stand Alone HE as condenser.
  • It is possible to define “Plate Material” for Plates Heat Exchangers.
  • Pressure Drop option available for Simplified Pipes calculation.
  • Fixed some minor bugs on models calculation.
  • Fixed some minor bugs on GUI.

IMST-ART© Version 3.6

Released: April, 2013
  • Resizable window for printing the circuitry.
  • Resizable windows for results and parametric windows.
  • Installation on user’s folder on Windows Vista/7/8 (administrator privileges not required for executing).
  • While calculating, navigation to other windows is allowed.
  • Different kind of cycles can be calculated simultaneously.

IMST-ART© Version 3.5

Released: March, 2012
  • Diabatic option available for capillary tube calculation.
  • Customized exportation of results for interaction with other models.
  • Define compressors by inputting the catalogue data.
  • Tubes and Wire Heat Exchangers.
  • Fans and pumps can be saved in order to be loaded in other heat exchangers.
  • It is possible to reverse the circuitry.

>80

Design parameters
Complete flexibility for your system design

>80

Design parameters
Complete flexibility for your system design

>80

Design parameters
Complete flexibility for your system design

>80

Design parameters
Complete flexibility for your system design
Scroll to Top